Heat Pump Heating Capacity At 5°F, 0°F And Below: What Homeowners Should Know

When homeowners compare heat pumps for a cold climate, one of the most important numbers is also one of the easiest to misunderstand: heating capacity at low outdoor temperatures.

A heat pump might be advertised as a 36,000 Btu/h, 48,000 Btu/h, or 60,000 Btu/h system. But that number does not necessarily represent the amount of heat it will deliver when the outdoor temperature falls to 5°F, 0°F, or -10°F.

Heating capacity changes with operating conditions.

As outdoor temperature falls, an air-source heat pump generally has to work harder to extract heat from the outdoor air. Its available heating capacity commonly decreases while the heating requirement of the house increases.

That makes low-temperature capacity particularly important for homeowners in northern and high-altitude parts of the United States.

The key question is therefore not:

“How many tons is this heat pump?”

It is:

“How many Btu/h can this particular heat pump actually deliver at the outdoor temperature that matters for my house?”

This article explains how to read that information, why capacity changes, how 5°F and 0°F data should be interpreted, what happens below 0°F, and how to compare equipment with your home’s heating load.

What Does Heat Pump Heating Capacity Mean?

Heating capacity is the rate at which a heat pump can deliver useful heat to the building.

It is commonly expressed in:

  • Btu/h in the United States,
  • watts or kilowatts in some technical documentation, and
  • tons in the HVAC industry when describing nominal equipment size.

One refrigeration ton corresponds to approximately 12,000 Btu/h of cooling capacity.

However, using tonnage as a shortcut for heating performance can be misleading.

A nominal 3-ton heat pump is not necessarily capable of delivering exactly 36,000 Btu/h of heating at every outdoor temperature.

The actual heating capacity depends on operating conditions and equipment design.

Why Does Heating Capacity Change With Outdoor Temperature?

An air-source heat pump moves heat from the outdoor environment into the building.

In heating mode, the outdoor coil acts as the evaporator.

The refrigerant must be colder than the outdoor air so that heat can flow from the air into the refrigerant.

When the outdoor temperature falls, the refrigerant system has to operate at increasingly demanding conditions to continue extracting useful heat.

Several effects occur simultaneously:

  • Outdoor evaporating temperature generally falls.
  • Suction pressure generally falls.
  • Compressor pressure ratio increases.
  • Compressor work increases.
  • Refrigerant mass flow and system operating conditions change.
  • Heat-transfer conditions become more difficult.
  • Heating capacity generally decreases.
  • COP generally decreases.

At the same time, the house loses heat more rapidly because the indoor-outdoor temperature difference is larger.

This is why low-temperature heat-pump selection requires more than looking at the equipment’s nominal rating.

Why 5°F Is An Important Reference Point

5°F (-15°C) is a particularly useful temperature when evaluating cold-climate heat pumps.

It is cold enough to reveal major differences between systems that may appear similar at milder temperatures.

Two heat pumps might have similar heating capacities at 47°F and 17°F but behave quite differently at 5°F.

For example, consider two hypothetical systems:

Outdoor Temperature Heat Pump A Heat Pump B
47°F 40,000 Btu/h 39,000 Btu/h
17°F 38,000 Btu/h 34,000 Btu/h
5°F 36,000 Btu/h 27,000 Btu/h

These figures are hypothetical and are not representative of any specific equipment.

The important point is the shape of the capacity curve.

At mild temperatures, the two systems appear similar.

At 5°F, their difference becomes much more significant.

What Happens At 0°F?

At 0°F (-17.8°C), the heat pump is operating in a considerably more demanding environment.

The outdoor coil must absorb heat from air that is already extremely cold.

The compressor must maintain the refrigeration cycle while working across a larger temperature lift between the outdoor and indoor sides.

The system’s controls may increase compressor speed and adjust refrigerant flow to maintain useful heating output, but there are physical limits to how much capacity can be produced.

Consequently, homeowners should look for actual performance data at or around 0°F when that temperature is relevant to the local climate.

What Happens Below 0°F?

Below 0°F, the same physical principles continue to apply.

There is no universal threshold at which all heat pumps stop operating.

Some cold-climate models are designed for operation well below 0°F.

But the lower the outdoor temperature becomes, the more important it is to distinguish among three different numbers:

  1. Minimum operating temperature
  2. Heating capacity at that temperature
  3. Heating load of the building at that temperature

Those three numbers answer different questions.

Minimum Operating Temperature Is Not Heating Capacity

Suppose a manufacturer states that a heat pump can operate down to -22°F.

That tells you something important about the system’s operating envelope.

But it does not tell you that the unit produces its nominal heating capacity at -22°F.

The actual capacity at that temperature could be substantially lower.

Therefore:

Operating temperature ≠ rated heating capacity.

This is one of the most important principles in evaluating cold-climate heat pumps.

Nominal Capacity Versus Actual Heating Capacity

Homeowners often encounter statements such as:

“3-ton heat pump.”

That generally describes the nominal equipment size, especially in cooling applications.

But heating performance is a different question.

A manufacturer may publish a detailed performance table showing different heating capacities at different outdoor temperatures.

A simplified hypothetical example might look like this:

Outdoor Temperature Nominal System Actual Heating Capacity
47°F 36,000 Btu/h class 42,000 Btu/h
17°F 36,000 Btu/h class 38,000 Btu/h
5°F 36,000 Btu/h class 34,000 Btu/h
0°F 36,000 Btu/h class 31,000 Btu/h
-10°F 36,000 Btu/h class 27,000 Btu/h

Again, these numbers are illustrative only.

The purpose is to demonstrate that one piece of equipment can have several different heating-capacity values depending on outdoor temperature.

Why Does The Heat Pump Have More Capacity At 47°F?

At 47°F, the outdoor air contains considerably more thermal energy that can be transferred to the refrigerant.

The refrigeration system also operates under less extreme pressure and temperature conditions.

The compressor does not have to overcome as large a temperature lift.

As a result, the system can generally produce more heat with a higher COP than it can under severe cold conditions.

This is one reason seasonal efficiency cannot be inferred from the lowest temperature alone.

Why Does Capacity Usually Fall At 17°F?

17°F (-8.3°C) is substantially colder than 47°F.

The outdoor evaporator has to operate at a lower temperature, which reduces suction pressure.

The compressor has to work harder to raise the refrigerant to the pressure required for indoor heat transfer.

The resulting refrigeration cycle is less favorable thermodynamically.

Capacity generally decreases, although the exact behavior depends on the system.

Why Can A Cold-Climate Heat Pump Retain More Capacity?

Cold-climate equipment may use several technologies to maintain useful output at low outdoor temperatures.

These can include:

  • variable-speed inverter compressors,
  • larger or optimized heat exchangers,
  • advanced electronic expansion valves,
  • optimized refrigerant circuits,
  • enhanced compressor technology,
  • low-temperature control algorithms,
  • vapor injection or other compressor enhancements in some designs, and
  • carefully designed defrost strategies.

These technologies do not eliminate the laws of thermodynamics.

They allow the equipment to operate more effectively within those physical constraints.

How Does A Variable-Speed Compressor Affect Low-Temperature Capacity?

A variable-speed compressor can change its rotational speed according to the heating requirement and system conditions.

At moderate loads, it can operate at a lower speed.

During severe cold, the system can increase compressor output when necessary and when the compressor remains within its approved operating envelope.

This is different from a fixed-speed compressor that has essentially one primary operating speed.

Variable-speed operation can provide several benefits:

  • better capacity modulation,
  • longer runtimes,
  • less frequent cycling,
  • more stable indoor temperature, and
  • greater ability to respond to changing outdoor conditions.

However, variable speed does not mean unlimited low-temperature capacity.

The compressor, heat exchangers and refrigeration circuit still have physical operating limits.

How Does Heating Load Change At 5°F?

The heat loss of a building increases as the outdoor temperature falls.

A simplified conductive heat-loss relationship is:

Q = U × A × ΔT

where:

  • Q = heat-transfer rate,
  • U = overall heat-transfer coefficient,
  • A = area, and
  • ΔT = indoor-outdoor temperature difference.

There are also infiltration and ventilation losses, which depend on air leakage, ventilation rates, wind and other conditions.

Therefore, if a home is maintained at 70°F:

Outdoor Temperature Indoor-Outdoor Temperature Difference
47°F 23°F
32°F 38°F
17°F 53°F
5°F 65°F
0°F 70°F
-10°F 80°F

The heat pump’s capacity is generally moving downward while the building’s heat loss is moving upward.

This is the central engineering challenge of cold-climate heating.

Heat Pump Capacity Versus Building Heat Loss

Imagine a hypothetical house with the following heating requirements:

Outdoor Temperature Building Heating Load Heat Pump Capacity Capacity Gap
17°F 32,000 Btu/h 38,000 Btu/h None
5°F 37,000 Btu/h 35,000 Btu/h 2,000 Btu/h
0°F 40,000 Btu/h 32,000 Btu/h 8,000 Btu/h
-10°F 48,000 Btu/h 27,000 Btu/h 21,000 Btu/h

These figures are hypothetical.

But the relationship illustrates exactly why supplemental heat can become necessary in extreme cold.

What Is The Balance Point?

The balance point is the outdoor temperature at which the available heat-pump capacity equals the building’s heat loss.

Above the balance point, the heat pump may have sufficient capacity to meet the building load.

Below the balance point, the heat pump may require supplemental heat.

The balance point is not a universal temperature such as 32°F or 0°F.

It depends on:

  • heat-pump capacity,
  • building insulation,
  • air leakage,
  • window performance,
  • home size and construction,
  • indoor setpoint,
  • outdoor design temperature, and
  • other building characteristics.

What Happens When Capacity Is Lower Than The Heating Load?

The heat pump does not necessarily stop working.

It may continue operating at maximum available output while supplemental heat supplies the difference.

For example:

Building load = 45,000 Btu/h

Heat-pump capacity = 32,000 Btu/h

Capacity gap = 13,000 Btu/h

A supplemental heating system would need to provide the remaining capacity if the goal is to maintain the desired indoor temperature.

What Is Auxiliary Heat?

Auxiliary heat is a supplemental heat source used when the heat pump cannot satisfy the heating demand by itself or when the controls determine that additional heat is necessary.

In many all-electric systems, this is electric resistance heat.

Resistance elements may be installed inside the air handler.

When energized, they provide direct electrical heating.

This can be effective but may consume substantially more electricity per unit of delivered heat than a heat pump operating with a COP greater than 1.

What Happens To Capacity During Defrost?

Another factor that complicates real-world heating capacity is defrost.

When frost accumulates on the outdoor coil, the heat pump needs to remove it.

During a defrost cycle, the refrigeration system temporarily changes its operation to transfer heat to the outdoor coil.

For a short period, the system’s normal heating behavior is interrupted or altered.

Indoor auxiliary heat may be used to maintain comfort during defrost, depending on the equipment and control system.

The frequency of defrost depends on temperature, humidity and equipment controls.

Does A Heat Pump Need More Defrost At 0°F Than At 30°F?

Not necessarily.

Frost formation depends heavily on moisture availability.

Air near freezing can contain much more water vapor than extremely cold air.

Consequently, moderately cold and humid conditions can sometimes produce significant frost accumulation.

At very low temperatures, the air may be extremely dry.

This does not eliminate frost, but it changes the conditions under which frost accumulates.

Why Capacity Data Must Be Interpreted Alongside COP

Heating capacity tells you how much heat the system can deliver.

COP tells you how much heat it delivers relative to the electricity consumed.

You need both pieces of information.

Consider two hypothetical heat pumps at 5°F:

Parameter Heat Pump A Heat Pump B
Heating capacity 36,000 Btu/h 40,000 Btu/h
COP 2.8 2.2

Heat Pump B provides more heat but uses more electrical energy per unit of delivered heat.

Whether that trade-off matters depends on the building’s heating load and electricity cost.

How To Convert Heating Capacity To Kilowatts

Homeowners sometimes find it useful to convert Btu/h to watts.

One watt is approximately 3.412 Btu/h.

Therefore:

Electrical or thermal power in watts ≈ Btu/h ÷ 3.412

For example:

34,120 Btu/h ÷ 3.412 ≈ 10,000 W

That represents approximately 10 kW of thermal output.

It does not mean the heat pump necessarily consumes 10 kW of electricity.

If the heat pump has a COP of 3, a 10 kW thermal output would theoretically require approximately 3.33 kW of electrical input under those particular conditions.

Actual performance depends on the equipment and operating conditions.

Why A 36,000 Btu/h Heat Pump Does Not Necessarily Need A 36,000 Btu/h Electrical Service

This is another common misunderstanding.

A heat pump transfers heat.

It does not convert every unit of electrical energy directly into heat.

If a system delivers 36,000 Btu/h with a COP of 3, the electrical input associated with the heating output would be substantially lower than 36,000 Btu/h equivalent.

However, the electrical service still has to accommodate the compressor, fans, controls, crankcase heaters where applicable, and potentially auxiliary resistance heat.

That last component can be significant.

Why Auxiliary Resistance Heat Can Change Electrical Demand Dramatically

Imagine a heat pump is delivering most of the home’s required heat but needs an additional 15,000 Btu/h of electric resistance heat.

15,000 Btu/h corresponds to approximately:

15,000 ÷ 3,412 ≈ 4.4 kW

That is a substantial additional electrical load.

If several resistance heating stages operate simultaneously, electrical demand can increase further.

This is why the electrical requirements of the complete system should be reviewed before installation.

Should You Size A Heat Pump For The Coldest Possible Temperature?

Equipment sizing should follow recognized load-calculation practices and the manufacturer’s application requirements rather than simply selecting equipment based on the coldest temperature imaginable.

The relevant design condition is typically a climate-specific heating design temperature used for HVAC load calculations.

A heat pump should be evaluated against the building’s calculated load at relevant design conditions.

Oversizing purely to cover an extremely rare temperature can create other problems, particularly in cooling operation and at milder heating conditions.

Why The Building Load Calculation Matters

Square footage alone is a poor method of determining heating capacity.

Two homes with the same floor area can have very different heating requirements.

Important factors include:

  • insulation levels,
  • air leakage,
  • window area,
  • window U-factor,
  • door construction,
  • ceiling and roof construction,
  • floor and foundation characteristics,
  • orientation,
  • occupancy,
  • ventilation, and
  • local outdoor design temperature.

A professional load calculation provides a much stronger basis for equipment selection than a rule such as “one ton per 500 square feet.”

How Insulation Changes Low-Temperature Heat Pump Performance

Improving the building envelope reduces the amount of heat the house loses.

Suppose a house requires 50,000 Btu/h at -10°F before weatherization.

After improving insulation and air sealing, its load might theoretically fall to 35,000 Btu/h.

The heat pump has not changed.

But its ability to cover the building load has changed dramatically.

This is why cold-climate heat-pump design should consider both:

Equipment performance + building performance.

How To Read A Manufacturer’s Low-Temperature Performance Data

When reviewing technical documentation, look for more than a single heating-capacity number.

Useful information includes:

Data Point What It Tells You
Heating capacity at 47°F Performance under relatively mild conditions
Heating capacity at 17°F Cold-weather performance
Heating capacity at 5°F Important cold-climate benchmark
Heating capacity at 0°F Useful for severe winter conditions
Heating capacity at -5°F or -10°F Extreme-cold performance where published
COP at different temperatures Efficiency under those operating conditions
Minimum operating temperature Lowest specified ambient operating condition
Electrical input Useful for evaluating electrical demand

Do Not Assume Every Manufacturer Uses The Same Data Format

Performance tables can vary in how they present:

  • indoor temperature,
  • outdoor temperature,
  • airflow,
  • fan speed,
  • compressor speed,
  • supplemental heat, and
  • test conditions.

Therefore, comparing two numbers without confirming that they were measured under comparable conditions can produce a misleading conclusion.

What Is A Capacity Curve?

A capacity curve describes how the available heating output changes with outdoor temperature.

A simplified conceptual curve might look like:

Outdoor temperature ↓ → heating capacity generally ↓

But the curve does not necessarily decline at a perfectly constant rate.

Inverter systems can have complex capacity behavior because compressor speed, refrigerant flow and controls change continuously.

This is why published manufacturer data is preferable to calculating low-temperature performance from one nominal rating.

Can A Heat Pump Increase Capacity At Low Temperatures?

Some systems can increase compressor speed as outdoor temperatures fall.

This can allow them to maintain relatively strong capacity across a wider range of temperatures.

However, “capacity retention” does not mean the system produces more heat at -10°F than it does at 47°F.

It means the system may retain a larger percentage of its useful heating capacity than another design.

Capacity Retention Is Often More Useful Than Nominal Capacity

Suppose two hypothetical heat pumps begin with similar output at moderate conditions.

Temperature System A System B
47°F 40,000 Btu/h 40,000 Btu/h
17°F 38,000 Btu/h 32,000 Btu/h
5°F 35,000 Btu/h 25,000 Btu/h
-5°F 31,000 Btu/h 20,000 Btu/h

System A retains more of its moderate-temperature capacity.

For a cold-climate application, that characteristic can be highly relevant.

How Do You Know If 5°F Capacity Is Enough?

Compare the heat pump’s published capacity with the building’s calculated heating load at the same outdoor condition.

For example:

Building load at 5°F = 38,000 Btu/h

Heat-pump capacity at 5°F = 40,000 Btu/h

The heat pump has enough nominal capacity under that simplified comparison.

If instead:

Building load at 5°F = 38,000 Btu/h

Heat-pump capacity at 5°F = 29,000 Btu/h

There is a 9,000 Btu/h capacity gap.

Supplemental heat would be needed if the goal is to maintain the design indoor condition under that scenario.

What If The Heat Pump Meets The Load At 5°F But Not At 0°F?

That can be a perfectly workable system design.

The heating system does not necessarily have to provide 100% of the building load with the heat pump at every possible outdoor temperature.

If the heat pump covers the load through most of the winter and supplemental heat handles the relatively small number of extreme-temperature hours, the overall system can still be designed appropriately.

The important question is how the complete system behaves over the expected heating season.

What Is A Good Cold-Climate Heat Pump Performance Curve?

There is no universal curve that qualifies as “good.”

Performance should be evaluated relative to the building, climate and system design.

For example, a heat pump with excellent low-temperature capacity may be unnecessary for a home whose design temperature is much warmer.

Conversely, a system with weak capacity retention may require substantial supplemental heat in a severe winter climate.

The right equipment is therefore determined by the application rather than by one universal capacity number.

5°F, 0°F And -10°F: What Should You Compare?

Question Why It Matters
What is capacity at 5°F? Shows cold-climate heating capability
What is COP at 5°F? Shows electrical efficiency in cold weather
What is capacity at 0°F? Shows how the system behaves during severe cold
What is COP at 0°F? Shows energy use under severe cold
What is capacity below 0°F? Important where extreme cold occurs
What is the minimum operating temperature? Defines the manufacturer’s operating range
What is the home’s design heating load? Determines how much heat the building actually needs

Common Mistakes When Looking At Heat Pump Capacity

Mistake 1: Assuming Nominal Tonnage Is The Heating Output

Nominal tonnage does not describe the complete heating performance curve.

Mistake 2: Looking Only At 47°F Capacity

A high heating capacity at mild temperatures tells you relatively little about performance during extreme cold.

Mistake 3: Looking Only At The 5°F Number

If your climate can reach -10°F, 5°F performance alone may not be enough information.

Mistake 4: Ignoring COP

A system can have high capacity but consume considerably more electricity than another system under the same conditions.

Mistake 5: Ignoring The Building Load

Capacity only becomes meaningful when compared with what the house requires.

Mistake 6: Treating Minimum Operating Temperature As Guaranteed Heating Capacity

The lowest operating temperature does not tell you how much heat the system produces there.

How To Choose A Heat Pump Based On Low-Temperature Capacity

A practical evaluation can follow this sequence:

  1. Determine the local winter design temperature.
  2. Calculate the home’s heating load.
  3. Find the manufacturer’s capacity at that temperature.
  4. Check capacity at 5°F and 0°F.
  5. Check lower-temperature data if relevant.
  6. Compare COP at the same temperatures.
  7. Determine the balance point.
  8. Estimate supplemental heat requirements.
  9. Check electrical requirements.
  10. Confirm installation conditions.

This approach gives you a much clearer picture of real cold-weather performance.

Questions To Ask Your HVAC Contractor

  • What is my home’s calculated heating load at the local design temperature?
  • What is the proposed heat pump’s heating capacity at that temperature?
  • What is its capacity at 5°F?
  • What is its capacity at 0°F?
  • What is its capacity at the expected minimum winter temperature?
  • At what temperature will supplemental heat become necessary?
  • How much auxiliary heat is being installed?
  • How will the thermostat control auxiliary heat?
  • What electrical service does the complete system require?
  • How will the outdoor unit be protected from snow and ice?

Frequently Asked Questions

1. What is heating capacity in a heat pump?

Heating capacity is the rate at which the heat pump delivers useful heat to the building, commonly measured in Btu/h.

2. Does heat-pump capacity stay constant?

No. Heating capacity changes with outdoor temperature and other operating conditions.

3. Why is 5°F important for heat pumps?

5°F is a useful low-temperature reference for evaluating cold-climate performance and comparing systems.

4. Why is 0°F important?

0°F represents a severe operating condition where differences in low-temperature design, capacity retention and supplemental heat strategy become particularly important.

5. Does heat-pump capacity always fall below 0°F?

Capacity generally decreases as outdoor temperature becomes increasingly cold, although the exact curve depends on the equipment.

6. Can a heat pump produce its nominal capacity at 0°F?

Some systems may retain a large percentage of their nominal capacity, but you should use the manufacturer’s published performance data rather than assume a particular percentage.

7. Is a 3-ton heat pump always 36,000 Btu/h?

A nominal 3-ton classification corresponds to approximately 36,000 Btu/h of cooling capacity, but it does not mean the system delivers exactly 36,000 Btu/h of heating under all conditions.

8. What is capacity retention?

Capacity retention describes how much heating output a system maintains as outdoor temperature falls compared with its output under a reference condition.

9. Does higher capacity mean better efficiency?

No. Heating capacity and efficiency are separate characteristics. COP should be considered alongside capacity.

10. What is COP?

COP is the ratio of useful heating output to electrical input under specified operating conditions.

11. Can a heat pump operate below -10°F?

Some systems are designed to operate at temperatures below -10°F, but the manufacturer’s specified operating range should be checked for the exact model.

12. Does operating at -10°F mean the heat pump can heat my entire house?

No. The system can operate while still producing less heat than the building requires. Supplemental heat may therefore be necessary.

13. What is a balance point?

It is the outdoor temperature at which the heat pump’s available capacity equals the building’s heating requirement.

14. Can insulation lower the required heat-pump capacity?

Improving insulation and air sealing reduces the building’s heat loss, which can reduce the required heating capacity.

15. Is square footage enough to size a heat pump?

No. A proper heating-load calculation considers the building envelope, air leakage, windows, climate and other factors.

16. Does a variable-speed compressor help with low-temperature operation?

It can. Variable-speed operation allows the compressor to adjust its output and can help maintain useful capacity across changing conditions.

17. Does a heat pump need backup heat at 5°F?

Not necessarily. It depends on the heat-pump capacity and the home’s heating load at 5°F.

18. Does a heat pump need backup heat at 0°F?

Some systems and homes will, while others may not. The answer depends on the relationship between equipment capacity and building load.

19. Is auxiliary heat expensive?

Electric resistance auxiliary heat can consume substantial electricity because its heating COP is approximately 1. The actual cost depends on how much auxiliary heat is used and local electricity rates.

20. Does defrost reduce heating capacity?

During defrost, the system temporarily changes its normal heating operation, so the effective heating contribution can be affected.

21. Can a heat pump have more capacity at 17°F than at 5°F?

Yes. Capacity generally decreases as outdoor temperature falls, so a system will often provide more heating output at 17°F than at 5°F.

22. Should I choose a heat pump based on the lowest temperature it can operate at?

No. Low-temperature operating capability is useful information, but heating capacity and COP at relevant temperatures are equally important.

23. What is the most important low-temperature capacity number?

The most useful number is the capacity at the outdoor design temperature for your specific home, supplemented by performance data at colder temperatures that the home may experience.

24. Why should I compare capacity at several temperatures?

A multi-temperature comparison shows how the heat pump’s output changes rather than giving you only one snapshot of performance.

25. Can two heat pumps with the same nominal tonnage have different cold-weather performance?

Yes. Compressor design, heat exchangers, controls, refrigerant circuit design and other engineering differences can produce significantly different low-temperature performance.

Final Takeaway

For a cold-climate heat pump, heating capacity at 5°F, 0°F and below is often more informative than the equipment’s nominal tonnage.

The important relationship is:

Heat Pump Capacity ≥ Building Heating Load

at the outdoor condition you are evaluating.

When the heat-pump capacity falls below the building load, supplemental heat may be required.

That does not automatically mean the heat pump is unsuitable. A properly designed system can use the heat pump for most of the heating season and supplemental heat during the most demanding conditions.

The most important thing is to understand the complete performance curve.

Before choosing a system, look for:

  • heating capacity at 17°F,
  • heating capacity at 5°F,
  • heating capacity at 0°F,
  • capacity at lower temperatures when relevant,
  • COP at those temperatures,
  • minimum operating temperature,
  • supplemental heat requirements, and
  • the relationship between equipment capacity and your home’s calculated heating load.